Geophysical Evaluation of Groundwater Potential Using Electrical Resistivity Method in Nigerian Defence Academy, Kaduna, Nigeria

Authors

  • Shaibu, I. Federal University Gusau
  • Udensi, E. E. ederal University of Technology, Minna

DOI:

https://doi.org/10.57233/ijsgs.v5i2.149

Keywords:

Evaluation, Groundwater Potentials, Resistivity, Depth, Aquifer

Abstract

The groundwater potential of the (NDA, Kaduna) was investigated using vertical electrical sounding (VES) method. A total number of 40 vertical electrical sounding VES points were used for the investigation using Schlumberger array and data obtained were analyzed using curve matching and computer iteration techniques. The data revealed a 3-layer (A, KH and H Curve type) and 4-layer (A and H-curve type). In the 3-layer system, the apparent resistivity of the first layer ranged from 18.9 Ωm to 183.2 Ωm with a corresponding thickness of 0.7 m to 14.8 m. The second layer has apparent resistivity value ranged from 13.5 Ωm to 423.8 Ωm with a corresponding thickness in the range of 4.5 m to 14.7 m while the third layer has resistivity values ranging from 1156.4 Ωm to 3732.7 Ωm with an infinite depth. For the four (4) layered model curves, first layer’s resistivity ranged from 29.5 Ωm to 244.7 Ωm, with a corresponding thickness ranging from 0.8 m to 13.0 m. The resistivity of the second layers ranged between 25.2 Ωm to 183.4 Ωm with a corresponding thickness ranging from 8.0 m to 14.2 m. The third layer resistivity ranged from 119.4 Ωm to 586.7 Ωm with a corresponding thickness ranging from 8.1 m to 20.4 m. The forth layer has a resistivity value ranging from 1318.3 Ωm to 3240.9 Ωm with an infinite depth. An integration of both isopach and iso-resistivity maps for both the 3- layer model curves and 4- layer model curves indicates that most of the northwest parts of the study area have low apparent resistivity values and thick overburden which implies good groundwater potential while, the southern portion has a little higher resistivity values and shallow overburden, an indication of poor groundwater potential. Future boreholes in the area should reached an expected depth of 40 m to 60 m depth

Author Biographies

Shaibu, I., Federal University Gusau

Department of Geology, Federal University Gusau, Zamfara State

Udensi, E. E., ederal University of Technology, Minna

Department of Physic, Federal University of Technology, Minna, Niger State

Downloads

Published

2019-12-24

How to Cite

Shaibu, I., & Udensi, E. E. (2019). Geophysical Evaluation of Groundwater Potential Using Electrical Resistivity Method in Nigerian Defence Academy, Kaduna, Nigeria. International Journal of Science for Global Sustainability, 5(2), 9. https://doi.org/10.57233/ijsgs.v5i2.149